Fenwal controller troubleshooting
WebThe Fenwal 35-535911-113 control cannot be serviced by the user. If any control faults are detected, the Fenwal 35-535911-113 control must be replaced by qualified service personnel. ... Before troubleshooting the system, check the following items: Verify all mechanical and electrical connections are secure and tight. Verify all system wiring ...
Fenwal controller troubleshooting
Did you know?
WebAug 7, 2024 · Connection to the IGN should be as printed on the FENWAL. Either IGN/120 OR IGN/240 depending on your voltage to the heater, AND IGN (first picture) or IGN/FS (second picture). Your post suggests that you are trying to heat the IGN with one high voltage LINE and one low voltage leg. Your current result is correct, it wont work! WebFenwal 35-704600-005 Ignition Control Board is the high quality replacement parts. If you are looking for the genuine replace part of your fenwal HVAC model then PartsAPS is the right place. You just have search with the parts number - Fenwal 35 …
WebThe Series 35-67 is a hot surface ignition system in which the ignition source is proven to be capable of ignition prior to the gas valve being opened and is suitable for … WebFeb 10, 2024 · 1. Cable and cable polarity from the control board to the display. 2. Check for 120vac on the primary of the transformer and 24vac on the secondary. If one of the 24vac interlocks has been shorted to ground or the 24vac output is low, the transformer may be damaged or a 24vac circuit may be miswired.
WebDetermine the control’s hardware type using the Hardware Type Series Guide and attach wire connectors according to the supplied wiring diagram that corresponds to the associated model number. Cautionary Note A … Webthe Fenwal control will go to a 1 flash air flow fault lockout. If everything is working properly, the Fenwal control will continue to power the blower motor for the 30 second pre-purge …
WebSep 24, 2024 · Sep 22, 2024. #6. The Fenwal has flame current test points, which are pointed out in the manual. Once the unit fires, you should get a good flame current. If the …
WebIND terminal of the Fenwal Ignition Control. Turn line power on to the heater but leave the thermostat selector switch off. Does the Fan go on with the Yellow/Back disconnected? Problem - Fan does not shut off Turn off all line power to the heater Remove Yellow/Back wire from IND terminal of the Fenwal Ignition Control. Turn line power heritage seeds australia victoriaWeba) The current Fenwal controller is almost one year old. (It is the 3rd one I have had. The original one lasted 18 years, the second one lasted 11 years. ) Upon opening this one, nothing looks burned, and everything is clean. I checked all the connections, especially the ground connection, as this unit uses the ignitor as the flame sensor. maurice oduor genghisWebFeb 3, 2024 · The circuit board may use LED lights to indicate a specific error code that you can then reference in your furnace manual to troubleshoot problems. A few simple things to check out include: Turn the igniter off and wait a few minutes before turning it back on to see if the issue is resolved. Examine your furnace filter. maurice odumbe cricketer